What am I seeing?
The green and blue curves join field values at different positions
at the same instant. Their arrows oscillate at fixed positions. They
are not material strings or photon paths. E and B are perpendicular,
in phase and transverse to propagation. Their display scales differ:
in SI units E = cB.
The wave travels through vacuum. Choose a linearly polarised or
unpolarised source. The source has been running before the starting
snapshot. Live source and filter changes travel forwards at c; the
detector can still receive radiation after the source is turned off.
Switching spectrum bands resets the scene scale and clock while
keeping captured readings.
Ideal polarisers project the electric field along their marked
transmission axes. A first ideal filter transmits 50% of unpolarised
input on average. For an already linearly polarised input aligned
with it, the first filter transmits 100%. The three-filter 0° / 45°
/ 90° example transmits 12.5% and 25% respectively.
The unpolarised animation samples changing electric-field directions
in short wave packets. It is a schematic illustration, not circular
polarisation. Intensity and RMS readings use the ensemble average; a
short trace need not have that average. Circular and elliptical
polarisation are not modelled.
The probe samples the local field component along its axis without
changing the wave. It represents an ideal receiving aerial in the
radio/microwave investigations and a directional field probe
elsewhere. Its response is relative intensity, not calibrated
received radio power. There is no geometric spreading, diffraction,
reflection, near field, material dispersion or photon simulation.
Abrupt switching is a teaching approximation.
Malus’s law, absolute field intensity and photon energy are optional
quantitative extensions. AQA A-level requires polarisation and
aerial alignment but does not require Malus’s law. Physical c is
299792458 m/s; the animation is slowed and its length scale is
labelled.