PhysicsUK

PHYSICSUK / A LEVEL

Quantum jumps. Measurable light.

Choose two states. Follow the energy from the atom to a photon.

HYDROGEN / PROBABILITY DENSITY
3sStationary probability density · |ψ|²
Drag to rotate the cloud0 photons detected
0.0 s
Ready. Each trial prepares the selected initial state.

Energy levels

→

Supported electric-dipole transition

|ΔE| = hf = hc / λ
Photon energy1.89 eV
FrequencyHz
Wavelength λ656.40 nmVisible

Light, resolved.

Model emission spectrum

START AN INVESTIGATION

Choose an experiment

Experiment controls

Photon source

These three controls describe the same photon. The source linewidth for single-atom resonance is 0.002 eV.

Optics & spectrum

Resolution controls model-line broadening and detector-bin width. It does not change the atom’s resonance condition. A comparison uses a dashed muted green curve, normalised separately. With “Selected initial state”, the comparison atom uses its ground state.

Cloud & playback

Density gives probability. Optional green/blue colours indicate opposite wavefunction signs, not charge.

Custom energy levels / eV

Four increasing negative energies. Zero is the ionisation limit. These define a fictional teaching atom.

KEEP THE EVIDENCE

Experiment notebook

Captures preserve the calculated transition, settings and detector count. Calculated energies are model values. Each trial’s photon arrivals are counted separately.

The physics behind the lab

This A-level lab connects discrete atomic energies with the photons absorbed and emitted. The diagram uses zero at the first ionisation limit: less negative levels have more energy. For a transition, the photon energy is the magnitude of the energy difference.

Three ways to picture an atom

The classical model illustrates the failure of a radiating planetary orbit: it loses energy and collapses. Its collapse time is illustrative. Bohr orbits are a historical representation with schematic radii. The cloud displays |ψ|² for normalised hydrogen eigenfunctions; it is a stationary probability distribution, not an electron trajectory. The s, p and d examples use real m = 0 orbitals. Repeated position measurements are independent samples of identically prepared atoms.

Clouds are automatically rescaled with n² to remain legible; the scale note states the distance represented by one scene unit in Bohr radii a₀. Multi-electron atoms use a schematic atomic picture and evaluated atomic-state energies; they do not use a hydrogen cloud as a many-electron solution.

Transitions and spectra

Hydrogen uses Eₙ = −13.6/n² eV, with s, p and d states through n = 6. Dipole transitions require Δl = ±1 here; fine structure, spin, polarisation and higher multipoles are omitted. In particular, 2s → 1s is not a supported one-photon dipole decay. Metastable and unsupported channels are not invented. Selected transitions of neutral helium, sodium, neon and mercury are taken from NIST. An unlisted pair may have other physical channels outside this subset.

Single-atom trials prepare the selected initial state. Photons retain their energy in flight. Absorption requires a supported upward transition within the declared 0.002 eV source bandwidth. Above the ionisation threshold, excess energy becomes electron kinetic energy; atomic recoil is neglected. Re-emission is shown sideways after an illustrative delay, so it need not return to the forward detector. Cascade delays are also illustrative, not measured atomic lifetimes.

Model emission spectra assume equal populations of the included upper states and weight photon rates by the tabulated A coefficients. Hydrogen and custom atoms use equal transition weights. Absorption spectra use equal peak optical depths for the occupied lower states. “Prepared lower states” is an artificial ensemble, not a thermal-equilibrium gas. No plasma temperature, collisional rates or calibrated lamp brightness are predicted. NIST line sets are incomplete; omitted lines may exist.

Gaussian instrument broadening is controlled by its full width at half maximum. Model curves are predictions, while the detector view counts the actual illustrated photons. Spectra-workspace photons are representative samples chosen to make events visible; their arrival counts are not a calibrated scan of the continuum. UV and IR markers are neutral display colours. Every wavelength is a vacuum wavelength derived from energy differences, so it differs slightly from familiar wavelengths tabulated in air.

A-level connections

AQA 3.2.2.2–3.2.2.3: excitation, ionisation, the electronvolt, photon emission and line spectra. OCR A 4.5.1 and 5.5.2: photons, atomic levels and stellar spectra. Orbital mathematics and selection-rule detail are enrichment. Balmer absorption needs atoms in n = 2; cold ground-state hydrogen does not acquire visible Balmer absorption simply because its emission spectrum contains those lines.

Sources

AQA: stellar absorption and the n = 2 population · NIST: transitions and line strengths

Controls & saved work

Use the initial/final selectors or select two lines on the diagram. Drag the 3D view to rotate; use the labelled zoom and reset buttons. Space plays/pauses when you are outside a form; Step advances 0.1 illustration seconds. Replay does not add detections. Changing the atom prepares a new trial; the notebook is retained. Local recovery and experiment files save settings and captured readings, but restart transient photons and timers. Escape closes a panel and restores focus.